HEPA Filters
Allies against Corona Virus

High Efficiency Filters for Critical Areas

High efficiency filters for the higher demands for air quality
High efficiency filters for the higher demands for air quality

Varying standards define what qualifies as a HEPA filter. The two most common standards require that an air filter must remove 99.95% (European Standard) of particles from the air that passes through, that have a size greater than or equal to 0.3 μm.
High-efficiency filters are used against bacteria, viruses, tobacco and metal oxide smoke, from class E12 against oil vapour and soot in the formation state as well as radioactive suspended matter and from class H14 against aerosols.

According to EU norm EN 1822-1:2009, the particle filter classes are divided into
E10, E11, E12 – EPA*-Filters (High-performance particulate filters)
H13, H14 – HEPA**-Filters (Suspended matter filters)
U15, U16, U17 – ULPA***-Filters (High-performance HEPA-Filters)

Fields of Application and Use

Room air Process air Gastronomy Cleanroom

E10 to E12: Final filters for rooms with high and highest requirements (e.g. in medicine, laboratories, production rooms in food- pharmaceutical- and electrical industries)
E12 to H13: Exhaust air filters in nuclear facilities; final filters in civil defence facilities and for cleanrooms of classes ISO 7 and ISO 5
H14: Final filter for cleanrooms of classes ISO 4 and ISO 3

The MAV filter for suspended particles BOL EUROVENT class 10 is a compact filter designed for the higher demands for air quality, e.g. the removal of biological pollution in critical hospital areas, pharma­ceutical plants etc.

The MAV filter for suspended particles AOL I + II, class S, E12 / H13 is used as a high-performance filter in clean-room systems and similar fields of application (semiconductor production, pharmaceutical industry, photo and film production, CD manufacturing, electronic industry, hospitals, nuclear plants, laboratories and food industry).

*Efficient Particulate Air, **High Efficiency-Particulate Air, ***Ultra Low Penetration Air

Technical Data

Filter class
DIN 241831
Separation efficiency
MPPS [%]2
Transmission rate
MPPS2
Filter class
DIN 241843
Transmission rate
[%]4
Retention (Separation efficiency)
[%]3
E10 85 15 Q 15 85
E11 95 0,5 R 2 98
E12 99,5 0,05 S 0,03 99,97
H13 99,95 0,05 0,08 99,97
H14 99,995 0,005 ST
U15 99,9995 0,0005 T
U16 99,99995 0,00005 U
U17 99,999995 0,000005 V

1Test with monodisperse aerosol 0.1–0.25 µm
2MPPS stands for Most Penetrating Particle Size
3Test with paraffin oil mist as test aerosol 0.3–0.5 µm
4Durchlassgrad in DIN 24184

Dimensions and Sizes

MAV-Type Width Height Depth
SF/30/30 305 305 292
SF/30/60 305 610 292
SF/60/60 610 610 292

The frames are optionally made of MDF or stainless, galvanized sheet steel.
Our HEPA filters are also available in special sizes. If required, please ask for other sizes and depths.